AirGuard GT Series


产品名称:AirGuard GT Series
产品编号:10437-863
产品型号:RF51050*,RF51051*,RF51052*,RF51053*,RF51054*,RF51055*,RF51…
更新时间:2009.12.03
出品厂家:英国MTL浪涌防雷保护器
浏览次数:41

AirGuard GT Series

Maximum discharge current
20kA (8/20μs)
Maximum power rating (VSWR)
1.25:1 or 1.20:1
Frequency Range
DC to 2.5GHz
Peak Pulse Current (8/20μs)
40kA
Impedance
50 Ω
Temperature Range
-40°F to +194°F
-40°C to +90°C
Dust & Waterproof
IP67
Salt Fog
MIL-STD-202-101 D/B
Temperture Shock
MIL-STD-202-107 D/B-1
Vibration
MIL-STD-202-204 D/D
Shock
MIL-STD-202-213/A
Model Connectors Frequency
Range(GHz)
VSWR Insertion
Loss
(dB)
Peak Pulse
Current
(8μs x 20μs)
Impedance
(Ω)
RF51050* BNC(f) Bulkhead to BNC(f) DC - 2.5 1.25:1 0.1 40kA 50
RF51051* BNC(m) to BNC(f) DC - 2.5 1.25:1 0.1 40kA 50
RF51052* TNC(f) Bulkhead(f) to TNC(f) DC - 2.5 1.25:1 0.1 40kA 50
RF51053* TNC(m) to TNC(f) DC - 2.5 1.25:1 0.1 40kA 50
RF51054* N(f) Bulkhead to N(f) DC - 2.5 1.20:1 0.1 40kA 50
RF51055* N(m) to N(f) DC - 2.5 1.20:1 0.1 40kA 50
RF51057* SMA(m) to SMA(f) DC - 2.5 1.20:1 0.2 40kA 50
RF51058* N(f) Bulkhead to SMA(f) DC - 2.5 1.20:1 0.2 40kA 50

* Add alpha suffi x to identify gas-tube voltage: A = 90V, B = 145V, C = 230V, D = 350V, E = 470V, F = 600V, G = 800V, H = 1,000V

Gas-Tube Voltage (Voltage should be defi ned by maximum RF power)
Parameter Gas-Tube Voltage
Voltage Code A B C D E F G H
Gas-Tube Voltage Rating 90 145 230 350 470 600 800 1000
Maximum RF Watts See notes 1, 2, 3 37 96 241 558 1006 1640 2915 4555
kA Transient Current for 8 x 20μs pulse 40 40 40 40 40 40 30 20
V dynamic at 5k/μs 600 600 650 800 1200 1500 1900 2200
Let-through Energy in mJ see notes 1 & 4 0.3 0.3 0.35 0.7 2.2 4.4 9 14

Note 1: Data given for 50Ω systems. For 75Ω systems multiply by 0.67, for 90Ω systems multiply by 0.55.
Note 2: For combined carrier applications the sum of all peak RF voltages plus any injection voltages should not exceed 60% of the Gas-Tube voltage rating. Peak RF volts = 1.4 x (RF power x Ohms) ^0.5.
Note 3: RF power is limited by the connector capability also.
Note 4: Let-through Energy based on the 6kV/3kA per ANSI C62.41.



Brackets

Model Connectors Diameter
RF51075 N 0.630” (1.6cm)
RF51077 BNC/TNC 0.505” (1.28cm)